US10C Clock Constantly Power-Cycling
Some US10C time clocks may experience continuous power-cycling or restarting loops when both the wired (Ethernet) and Wi-Fi network interfaces are enabled simultaneously. This occurs because the device attempts to maintain two concurrent network connections, which can cause instability in its power or communication handling routines.
⚙️ Resolution
To resolve the issue:
-
Access the device’s settings menu.
-
Navigate to the Network Configuration section.
-
If the device is using a wired (Ethernet) connection:
-
Disable the Wi-Fi interface.
-
Save the configuration.
-
-
Reboot the device once after saving changes.
After disabling Wi-Fi, the clock should stabilize and remain powered on without repeated restarts.
💡 Additional Notes
-
If you plan to use Wi-Fi exclusively, disconnect the Ethernet cable and verify that Wi-Fi credentials are correctly configured.
-
Always ensure that only one network interface (either Wi-Fi or LAN) is active at a time.
-
If the issue persists even with Wi-Fi disabled, check for faulty cables, unstable PoE power sources, or firmware updates.